Charging
Cycle Applications: Limit initial current
to 560mA. Charge until battery voltage (under charge) reaches 7.20 to 7.35
volts at 68º F (20º C). Hold at 7.20 to 7.35 volts until current drops to
approximately 28mA. Battery is fully charged under these conditions, and
charger should either be disconnected or switched to "float" voltage.
"Float" or "Stand-by Service": Hold battery
across constant voltage source of 6.75 to 6.90volts continuously. When
held at this voltage, the battery will seek its own current level and